Feb. 06. 2012 09:23

Distributors Contact Sitemap References Disclaimer Privacy


Noxious gas test

Noxious gas tests are used to control the corrosion resistivity of metals and to determine the ageing speed of plastics and glass. Another important field for noxious gas tests is the control of coatings and coverings for leak tightness. Industrial and vehicle waste gases among others cause high noxious gas loads. Noxious gas tests are therefore often carried out for objects which are later used or fitted in heavily industrialized areas.
Technolab GmbH equipment includes a modular noxious gas – climatic simulation chamber in which a multitude of standard tests can be carried
out. TechnoLab can also carry out customized noxious gas tests with differing gas concentrations and differing cas compositions. Tests with rarely used gases can be carried out after prior inquiry and feasibility checks.

Schadgasanlage

Chamber volume up to 300 liters

  • various gases: NO2 ; SO2 ; Cl2 ; H2S ; O3
  • Temperature up to 60°C
  • Humidity up to 99%
  • Flowing gases
  • Still gases
  • Circulating air method
  • various flowing speeds
  • various gas concentrations / compositions
  • Parameter monitoring / recording
  • Online / offline testing

Standards

e.g. DIN IEC 62716 Ed. 1, DIN EN 60068-2-60; DIN IEC 60068-2-49; IEC 512; DIN EN 19313; DIN EN 13919; EN 61300-2-28; DIN EN ISO 3231; DIN EN 54-3; EN ISO 6988; DIN 50018; Bellcore GR-1217; ETSI EN 300 019-1-3 and VW 801.01 and BMW-GS-95003

Data sheet