Noxious gas test mono / multi

multiple gas bottles
Noxious gas test chamber for complete solar panels
Noxious gas tests are used to ascertain the corrosion resistance of metals and determine the aging speed of plastics and glass. Another important field of application for noxious gas tests is the check of coatings and coverings for leak tightness. Technolab GmbH equipment includes several noxious gas climatic simulation chambers which can also run customized tests.
The largest test chamber with its 5.4m3 can take up large objects such as complete solar panels.

Specifications

  • Chamber volume up to 4.800 liters
  • Temperature change +20 °C to +70 °C
  • various gases, i.a.:
    • nitrogen dioxide (NO2)
    • sulfur dioxide (SO2)
    • chlorine (Cl2)
    • hydrogen sulfide (H2S)
    • ammonia (NH3)
    • ozone (O3)
  • cyclic temperature and humidity regulation
  • flowing gases
  • still gases
  • circulation
  • various flow velocities
  • various gas concentrations / compositions

Standards

  • IEC 60068-2-60 (Method 1-4)
  • IEC 60068-2-49
  • IEC 60068-2-42
  • IEC 60512-11-7
  • IEC 62716 (82/722/CDV)
  • IEC 61300-2-28
  • ISO 16750-4
  • ISO 1431
  • DIN EN ISO 3231
  • EN ISO 6988
  • ISO 10960
  • ASTM D 1149
  • DIN 50018
  • DIN V 40046-36
  • DIN V 40046-37
  • Bellcore GR-1217
  • TSM 0508G
  • UL 1332-7
  • UL 50
  • NEMA 250
  • ETSI EN 300 019-1-3
  • VW 80000
  • BMW GS 95003
  • JDQ 53.3